Dryer Repair Labor Prices
Dryer Repair Labor Prices
Local Appliance Repair — detailed labor-price reference for dryer repair labor prices; 24 itemized operations.
Labor-only estimates for Economy, Middle and Premium model classes. Replacement parts are quoted separately. Exact operation and equipment class must be verified from model number and diagnosis.
Appliance age scenarios: 0–5 years ×1.00; over 5 through 10 years ×1.25; over 10 years ×1.50. Adjustments above ×1.00 require inspection, explanation and agreement before work. Never count identical access work twice.
Standard diagnostic visit: $65, credited toward an eligible completed repair. Six-month workmanship warranty applies to qualifying work; part warranties vary under the Company Facts policy.
Dryer — labor by operation
Operation / code | Economy labor | Middle labor | Premium labor |
Door switch replacement (LAR-DRY-062) | $175 | $195 | $230 |
Thermal fuse replacement (LAR-DRY-063) | $185 | $210 | $245 |
Start switch replacement (LAR-DRY-064) | $185 | $210 | $245 |
Drum drive belt replacement (LAR-DRY-065) | $200 | $225 | $265 |
Door latch replacement (LAR-DRY-066) | $175 | $195 | $230 |
Flexible vent hose replacement (LAR-DRY-067) | $175 | $195 | $230 |
Electric heating element replacement (LAR-DRY-068) | $250 | $280 | $335 |
High-limit thermostat replacement (LAR-DRY-069) | $205 | $235 | $275 |
Cycling thermostat replacement (LAR-DRY-070) | $205 | $235 | $275 |
Gas burner igniter replacement (LAR-DRY-071) | $230 | $260 | $300 |
Gas flame sensor replacement (LAR-DRY-072) | $220 | $245 | $290 |
Drum roller / drum bearing replacement (LAR-DRY-073) | $225 | $255 | $295 |
Idler pulley replacement (LAR-DRY-074) | $220 | $245 | $290 |
Drum assembly replacement (LAR-DRY-075) | $220 | $245 | $285 |
Control / interface board replacement (LAR-DRY-076) | $230 | $260 | $300 |
Drive motor replacement (LAR-DRY-077) | $230 | $260 | $300 |
Timer assembly replacement (LAR-DRY-078) | $230 | $260 | $300 |
Gas valve coil replacement (LAR-DRY-079) | $255 | $285 | $335 |
Blower wheel replacement (LAR-DRY-080) | $245 | $275 | $320 |
Wiring harness repair (LAR-DRY-081) | $275 | $310 | $360 |
Complete gas valve assembly replacement (LAR-DRY-082) | $365 | $410 | $480 |
Internal lint and accessible exhaust cleaning (LAR-DRY-083) | $180 | $205 | $235 |
Moisture sensor cleaning (LAR-DRY-084) | $125 | $140 | $165 |
Gas burner area cleaning (LAR-DRY-085) | $160 | $180 | $210 |
What each listed service includes
LAR-DRY-062 — Door switch replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access dryer door switch; replace switch and reconnect. Reassemble and restore all disturbed guards/connections. Verification: Verify door sensing and safe start/stop.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-063 — Thermal fuse replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Locate failed dryer thermal fuse and replace it after diagnosing overheating or blocked airflow cause. Reassemble and restore all disturbed guards/connections. Verification: Verify run/heat conditions and airflow; fuse is not a root-cause fix.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-064 — Start switch replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access dryer start switch/control; replace switch and reconnect. Reassemble and restore all disturbed guards/connections. Verification: Confirm start/stop function.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-065 — Drum drive belt replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access drum drive belt; remove broken belt, route replacement on motor/idler and reseat panels. Reassemble and restore all disturbed guards/connections. Verification: Verify drum rotation and noise under operation.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-066 — Door latch replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access dryer door catch/latch; replace damaged catch and adjust closure. Reassemble and restore all disturbed guards/connections. Verification: Confirm door latches and sensing reliably.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-067 — Flexible vent hose replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Remove deteriorated accessible flexible dryer exhaust duct and fit approved duct material with secure clamps. Reassemble and restore all disturbed guards/connections. Verification: Verify exhaust airflow and safe clearance; excludes building-duct cleaning.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-068 — Electric heating element replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. On an electric resistance dryer, access heater housing and replace failed heating element. Reassemble and restore all disturbed guards/connections. Verification: Check controlled heat and airflow; not applicable to gas or heat-pump variants.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-069 — High-limit thermostat replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access failed high-limit thermostat; replace specified thermostat and diagnose underlying heat/airflow restriction. Reassemble and restore all disturbed guards/connections. Verification: Check temperature cycling and airflow; avoid simply bypassing limiter.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-070 — Cycling thermostat replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access cycling thermostat on equipped designs; replace and reseat its thermal interface. Reassemble and restore all disturbed guards/connections. Verification: Verify controlled cycling and temperature response.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-071 — Gas burner igniter replacement
Included work: Qualified gas-appliance technician isolates electrical and gas supplies where required. On a gas dryer, qualified technician accesses burner igniter and replaces diagnosed igniter. Reassemble and restore all disturbed guards/connections. Verification: Verify safe ignition and heating sequence.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-072 — Gas flame sensor replacement
Included work: Qualified gas-appliance technician isolates electrical and gas supplies where required. On a gas dryer, qualified technician replaces diagnosed flame/radiant sensor. Reassemble and restore all disturbed guards/connections. Verification: Verify gas ignition sequence and temperature response.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-073 — Drum roller / drum bearing replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access drum support rollers/bearing; replace diagnosed support units in recommended set and refit drum. Reassemble and restore all disturbed guards/connections. Verification: Verify smooth drum rotation and vibration/noise.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-074 — Idler pulley replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access belt tensioner; replace worn idler pulley and refit drive belt. Reassemble and restore all disturbed guards/connections. Verification: Verify proper tension and quiet drum rotation.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-075 — Drum assembly replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Disassemble cabinet sufficiently to remove and replace compatible drum assembly. Reassemble and restore all disturbed guards/connections. Verification: Verify drum support, sealing/felt contact and rotation.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-076 — Control / interface board replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access dryer main control/interface board; replace diagnosed module and configure as specified. Reassemble and restore all disturbed guards/connections. Verification: Verify controls, codes and drying sequence.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-077 — Drive motor replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access motor/blower drive; replace diagnosed motor and restore belt/blower connections. Reassemble and restore all disturbed guards/connections. Verification: Check drive, airflow and controlled heat where equipped.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-078 — Timer assembly replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access mechanical timer on applicable models; replace timer and verify wiring harness. Reassemble and restore all disturbed guards/connections. Verification: Check timer advance and cycle selection.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-079 — Gas valve coil replacement
Included work: Qualified gas-appliance technician isolates electrical and gas supplies where required. On gas dryer, qualified technician replaces diagnosed gas-valve coils without replacing full valve where manufacturer permits. Reassemble and restore all disturbed guards/connections. Verification: Verify burner cycling and correct ignition.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-080 — Blower wheel replacement
Included work: Isolate electrical power; protect dryer and nearby surfaces. Access blower housing; replace broken blower wheel and clean safe accessible debris. Reassemble and restore all disturbed guards/connections. Verification: Check exhaust airflow and vibration.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-081 — Wiring harness repair
Included work: Isolate electrical power; protect dryer and nearby surfaces. Find and repair localized damaged dryer harness/connectors; restore insulation and strain relief. Reassemble and restore all disturbed guards/connections. Verification: Verify affected circuits and appliance function.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-082 — Complete gas valve assembly replacement
Included work: Qualified gas-appliance technician isolates electrical and gas supplies where required. On gas dryer, qualified technician replaces authorized complete gas valve assembly. Reassemble and restore all disturbed guards/connections. Verification: Perform gas-joint leak check and safe ignition/heat verification.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-083 — Internal lint and accessible exhaust cleaning
Included work: Isolate electrical power; protect dryer and nearby surfaces. Open accessible lint chambers and service panels; remove lint and restore duct connections as agreed. Reassemble and restore all disturbed guards/connections. Verification: Verify airflow; excludes full building vent run/chimney cleaning.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-084 — Moisture sensor cleaning
Included work: Isolate electrical power; protect dryer and nearby surfaces. Clean accessible moisture-sensing bars and remove film without damaging sensors. Reassemble and restore all disturbed guards/connections. Verification: Verify sensor response or diagnostic mode if available.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.
LAR-DRY-085 — Gas burner area cleaning
Included work: Qualified gas-appliance technician isolates electrical and gas supplies where required. Qualified gas-appliance technician opens approved burner-service access and removes accessible lint/debris. Reassemble and restore all disturbed guards/connections. Verification: Verify safe burner ventilation and ignition.
Additional conditions: Stacked removal, restricted building exhaust, seized fasteners, gas-system work or additional diagnosed operation: quote incremental labor before repair.


Comments